Section 17. Structural Requirements. —

Food establishments shall be constructed in accordance with the following requirements:

  1. No person shall use any room or place for or in connection with the preparation, storage, handling or sale of any article of food —

    1. Which is at anytime used or in direct communication with a sleeping apartment or toilet;

    2. In which any animal is kept; or

    3. Which is or has been used for any purpose which would be likely to contaminate the food or to affect injuriously its wholesomeness or cleanliness; or

    4. Which is not used exclusively for the purpose; Provided, That in department stores or multi-purpose business establishments, food may be manufactured, prepared, cooked, stored, or sold only in the area set aside exclusively for said purpose and for which a sanitary permit has been issued.

  2. No sanitary permit shall be issued for any premises to be used for the preparation, handling and sale of food unless it is constructed in accordance with the following requirements:

    1. Floors. —

      The Floors shall be —

      1. Constructed of concrete or other impervious and easily cleaned material that is resistant to wear and corrosion and shall be adequately graded and drained; all angles between the floors and walls shall be rounded off to a height of not less than 3 inches (7.62 cm.) from the floor; or

      2. Constructed of wood with dovetailed or tongue and grooved floor boards laid on a firm foundation and tightly clamped together with all angles between the floor and walls rounded off to a height of 3 inches (7.62 cm.); or

      3. Constructed in accordance with the requirements of sub-clause (i) and (ii) of this clause and covered with linoleum, smooth surfaced rubber or similar material fixed to the floor with cement or suitable adhesive: Provided, That with the approval in writing of the local authority, floors may be covered with carpets or other floor covering in those parts of the premises where such carpets or coverings can be satisfactorily cleaned and maintained.

    2. Walls

      1. The internal surface of walls shall have a smooth, even, non-absorbent surface capable of being readily cleaned without damage to the surface and constructed of dust-proof materials;

      2. The walls, where subject to wetting or splashing, shall be constructed of impervious, non-absorbent materials to a height of not less than 79 inches (2 meters) from the floor;

      3. The internal walls shall be painted in light colors or treated with such other wall finish as the health authority may prescribe.

      1. All ceilings or, if no ceiling is provided, the entire under-surface of the roof shall be dust-proof and washable.

      2. The ceiling or undersurface of the roof of rooms in which food is prepared or packed or in which utensils or hands are washed shall be smooth, non-absorbent and light coloured.

    3. Lighting

      1. The general standards of illumination provided shall permit effective inspection and cleaning and shall be of sufficient intensity appropriate to the purpose for which any room or place is used;

      2. In rooms where food is prepared or packed or in which utensils or hands are washed there shall be a minimum illumination intensity of 20 foot-candles; in premises where food is consumed, there shall be a minimum illumination intensity of 5 foot-candles. Intensities of illumination shall be measured at a point 30 inches (76.20 cm.) above the floor;

      3. All lighting shall be reasonably free from glare and distributed so as to avoid shadows;

      4. At other areas or working surfaces, the illumination shall be of such intensity as may be required by the health authority.

    4. Ventilation

      1. Ventilation shall be provided which shall be effective and suitable to maintain comfortable condition;

      2. The ventilation shall be adequate to prevent the air from becoming excessively heated, prevent condensation and the formation of excess moisture on walls, ceilings and for the removal of objectionable odours, fumes and impurities;

      3. In the absence of effective natural ventilation, mechanical ventilation with airflow from a clean area, and discharging in such a manner as not to create a nuisance, shall be provided;

      4. Canopies, air ducts, fans or other appliances shall be provided as required by the health authority in particular circumstances;

      5. Effective provision shall be made for securing and maintaining a reasonable temperature;

    5. Overcrowding —

      There shall be sufficient floor space to enable every person working thereon to carry out his duties efficiently and to permit easy access for cleaning. Working spaces, aisles or passageways and areas to which customers have access shall be unobstructed and sufficient to permit movement of employees and customers without contamination of food by clothing or personal contact.

    6. Changerooms

      (1) There shall be provided adequate and suitable lockers or other facilities for the orderly storage of clothing and personal belongings of employees or persons engaged or employed in the premises. Such facilities shall be so situated and arranged so that there is no contamination of food by contact with clothing, and where the number of persons engaged or employed is four or more of either sex, there shall be provided separate changing rooms for each sex.

    7. Wash-Hand Basins

      1. Wash-hand basins shall be installed in convenient places and as near as practicable to where the person for whose use they are provided are working while handling food for sale or in such locations as may be otherwise prescribed in any particular case.

      2. If required in writing by the local health authority an additional wash-hand basin shall be installed as near as practicable to the toilet facilities: Provided, that the wash-hand basins specified in this Code need not be installed in premises where only food in sealed containers is sold: and, Provided, further, that wash-hand basins specified in this regulation shall be installed under specifications of the National Plumbing Code of the Philippines.

    8. Wash-Hand Basins Maintenance

      1. An adequate supply of soap, clean towels, roller towels presenting a clean surface to each user from a continuous roller towel dispenser or other hand drying services approved by health authorities.

      2. The wash-hand basin and all hand washing facilities shall, at all times, be maintained in good repair and in a clean condition.

      3. All wash-hand basins shall, at all times, while the premises are being used, be supplied with hot and cold or tempered running water at a minimum temperature of 100ºF (37.8ºC).